<< previous testnext test >>

2026-05-18-001 / SDM_RICO3D

/home/regtester/git/amrex/Tools/Plotfile//fcompare.gnu.ex --abort_if_not_all_found -n 0 --rel_tol 1e-12 --abs_tol 1e-12 /home/regtester/RegTesting/rt-ERF/ERF-GPU-benchmarks/SDM_RICO3D_plt00010 SDM_RICO3D_plt00010

variable nameabsolute errorrelative error
(||A - B||)(||A - B||/||A||)
level = 0
density2.886579864e-152.519997249e-15
rhotheta3.410605132e-139.99489359e-16
x_velocity1.474376177e-131.515674153e-14
y_velocity1.576516695e-134.138308271e-14
z_velocity1.963255947e-133.062716316e-12
temp7.958078641e-132.666868298e-15
theta7.958078641e-132.51396065e-15
pressure1.600710675e-101.591400851e-15
qv3.122502257e-171.980255972e-15
qc1.291207076e-364.090659614e-13
qrain0.00.0
qt3.122502257e-171.980255972e-15
qp0.00.0
qsat1.002670169e-154.882541971e-14
rain_accum1.524440538e-371.234936333e-11
rel_humidity3.963496198e-144.283783195e-14
super_droplets_moisture_mass_flux_x1.18195957e-353.019775146e-13
super_droplets_moisture_mass_flux_y5.474864939e-363.116464251e-13
super_droplets_moisture_mass_flux_z3.820930612e-376.799989781e-12
super_droplets_moisture_number_density9.198248412e-222.05452285e-14
super_droplets_moisture_mass_density1.418674745e-363.069211391e-13
super_droplets_moisture_radius3.022848831e-201.021481267e-13
super_droplets_moisture_mass_density_H2O1.413531957e-364.107044634e-13
super_droplets_moisture_mass_flux_x_H2O1.18195957e-354.055609332e-13
super_droplets_moisture_mass_flux_y_H2O5.435192005e-364.155300373e-13
super_droplets_moisture_mass_flux_z_H2O2.837142859e-376.779622636e-12
super_droplets_moisture_aerosol_mass_density_NH4HSO42.571393892e-382.071505073e-14
super_droplets_moisture_aerosol_mass_flux_x_NH4HSO42.350988702e-371.947273107e-14
super_droplets_moisture_aerosol_mass_flux_y_NH4HSO41.528142656e-373.245647974e-14
super_droplets_moisture_aerosol_mass_flux_z_NH4HSO41.144959048e-374.682217086e-12
accum_NH4HSO47.650681472e-321.2372796e-11