<< previous testnext test >>

2026-06-26-001 / SDM_RICO3D

/home/regtester/git/amrex/Tools/Plotfile//fcompare.gnu.ex --abort_if_not_all_found -n 0 --rel_tol 1e-12 --abs_tol 1e-12 /home/regtester/RegTesting/rt-ERF/ERF-GPU-benchmarks/SDM_RICO3D_plt00010 SDM_RICO3D_plt00010

variable nameabsolute errorrelative error
(||A - B||)(||A - B||/||A||)
level = 0
density3.108624469e-152.713843235e-15
rhotheta2.842170943e-138.329077537e-16
x_velocity1.60760294e-131.652632376e-14
y_velocity1.60760294e-134.219908783e-14
z_velocity2.079829364e-133.244602385e-12
temp8.526512829e-132.857358887e-15
theta7.958078641e-132.51396065e-15
pressure1.455191523e-101.446728056e-15
qv3.469446952e-172.200291188e-15
qc1.122964447e-363.557651849e-13
qrain0.00.0
qt3.469446952e-172.200291188e-15
qp0.00.0
qsat9.263423362e-164.510860415e-14
rain_accum1.955292508e-371.583722778e-11
rel_humidity4.740652315e-145.123740676e-14
super_droplets_moisture_mass_flux_x1.060295904e-352.708937736e-13
super_droplets_moisture_mass_flux_y4.478633477e-362.549377851e-13
super_droplets_moisture_mass_flux_z3.908547415e-376.955934209e-12
super_droplets_moisture_number_density1.316871535e-212.941366685e-14
super_droplets_moisture_mass_density1.235003752e-362.67185104e-13
super_droplets_moisture_radius2.604626313e-208.801554708e-14
super_droplets_moisture_mass_density_H2O1.231330332e-363.577654206e-13
super_droplets_moisture_mass_flux_x_H2O1.053242938e-353.613948791e-13
super_droplets_moisture_mass_flux_y_H2O4.522714515e-363.457694702e-13
super_droplets_moisture_mass_flux_z_H2O2.894654839e-376.917068243e-12
super_droplets_moisture_aerosol_mass_density_NH4HSO43.636685648e-382.929699473e-14
super_droplets_moisture_aerosol_mass_flux_x_NH4HSO42.277520305e-371.886420346e-14
super_droplets_moisture_aerosol_mass_flux_y_NH4HSO41.476714778e-373.136419124e-14
super_droplets_moisture_aerosol_mass_flux_z_NH4HSO41.218520716e-374.983065417e-12
accum_NH4HSO49.796438264e-321.584129141e-11