<< previous testnext test >>

2026-07-23 / SDM_RICO3D

/home/regtester/git/amrex/Tools/Plotfile//fcompare.gnu.ex --abort_if_not_all_found -n 0 --rel_tol 1e-12 --abs_tol 1e-12 /home/regtester/RegTesting/rt-ERF/ERF-GPU-benchmarks/SDM_RICO3D_plt00010 SDM_RICO3D_plt00010

variable nameabsolute errorrelative error
(||A - B||)(||A - B||/||A||)
level = 0
density3.108624469e-152.713843235e-15
rhotheta3.97903932e-131.166070855e-15
x_velocity1.580957587e-131.625240679e-14
y_velocity1.505462421e-133.951791734e-14
z_velocity2.068900606e-133.227553163e-12
temp8.526512829e-132.857358887e-15
theta7.958078641e-132.51396065e-15
pressure1.746229827e-101.736073668e-15
qv3.469446952e-172.200291188e-15
qc9.657420776e-373.059557315e-13
qrain0.00.0
qt3.469446952e-172.200291188e-15
qp0.00.0
qsat7.91033905e-163.851970692e-14
rain_accum1.712717654e-371.387245091e-11
rel_humidity4.207745263e-144.547769827e-14
super_droplets_moisture_mass_flux_x8.939634538e-362.283976883e-13
super_droplets_moisture_mass_flux_y3.908518716e-362.224850925e-13
super_droplets_moisture_mass_flux_z3.764107399e-376.698878224e-12
super_droplets_moisture_number_density1.105113298e-212.468383097e-14
super_droplets_moisture_mass_density1.064557071e-362.303100629e-13
super_droplets_moisture_radius2.260519178e-207.638747683e-14
super_droplets_moisture_mass_density_H2O1.060883652e-363.082418063e-13
super_droplets_moisture_mass_flux_x_H2O8.916124651e-363.059352855e-13
super_droplets_moisture_mass_flux_y_H2O3.898233141e-362.980267957e-13
super_droplets_moisture_mass_flux_z_H2O2.794245638e-376.677130317e-12
super_droplets_moisture_aerosol_mass_density_NH4HSO43.085672671e-382.485805613e-14
super_droplets_moisture_aerosol_mass_flux_x_NH4HSO42.497925495e-372.068977154e-14
super_droplets_moisture_aerosol_mass_flux_y_NH4HSO41.506102137e-373.198835389e-14
super_droplets_moisture_aerosol_mass_flux_z_NH4HSO41.180043078e-374.825713475e-12
accum_NH4HSO48.621094377e-321.394070612e-11