<< previous testnext test >>

2026-06-02 / SDM_RICO3D

/scratch/AMReX_RegTesting/amrex/Tools/Plotfile//fcompare.gnu.ex --abort_if_not_all_found -n 0 --rel_tol 1e-12 --abs_tol 1e-12 /scratch/AMReX_RegTesting/rt-ERF/ERF-benchmarks/SDM_RICO3D_plt00010 SDM_RICO3D_plt00010

variable nameabsolute errorrelative error
(||A - B||)(||A - B||/||A||)
level = 0
density9.072439355e-087.920280502e-08
rhotheta2.841408462e-058.326843517e-08
x_velocity5.587878524e-065.744397652e-07
y_velocity1.87356223e-064.918043747e-07
z_velocity1.2327178e-061.923063025e-05
temp7.63524497e-072.558682024e-09
theta1.23600438e-063.904543439e-09
pressure0.0013607776491.352863289e-08
qv5.86700201e-083.720786989e-06
qc3.175785573e-291.006117301e-05
qrain0.00.0
qt5.86700201e-083.720786989e-06
qp0.00.0
qsat6.572991387e-103.200744104e-08
rain_accum2.424357277e-300.0001963951241
rel_humidity3.107532153e-063.358649372e-06
super_droplets_moisture_mass_flux_x3.521950018e-288.998190296e-06
super_droplets_moisture_mass_flux_y1.37054769e-287.801585845e-06
super_droplets_moisture_mass_flux_z2.904971349e-305.169885951e-05
super_droplets_moisture_number_density1.614995651e-143.607257947e-07
super_droplets_moisture_mass_density3.614399642e-297.819520714e-06
super_droplets_moisture_radius1.528429634e-125.164870379e-06
super_droplets_moisture_mass_density_H2O3.637151887e-291.056781566e-05
super_droplets_moisture_mass_flux_x_H2O3.537370342e-281.213763358e-05
super_droplets_moisture_mass_flux_y_H2O1.379355493e-281.054541659e-05
super_droplets_moisture_mass_flux_z_H2O1.774916901e-304.241332704e-05
super_droplets_moisture_aerosol_mass_density_NH4HSO44.477749619e-313.607257945e-07
super_droplets_moisture_aerosol_mass_flux_x_NH4HSO47.346108096e-306.084622493e-07
super_droplets_moisture_aerosol_mass_flux_y_NH4HSO41.590233639e-303.377524061e-07
super_droplets_moisture_aerosol_mass_flux_z_NH4HSO41.130054479e-304.621266058e-05
accum_NH4HSO48.478636145e-250.0001371177663