<< previous testnext test >>

2026-06-28 / SDM_RICO3D

/scratch/AMReX_RegTesting/amrex/Tools/Plotfile//fcompare.gnu.ex --abort_if_not_all_found -n 0 --rel_tol 1e-12 --abs_tol 1e-12 /scratch/AMReX_RegTesting/rt-ERF/ERF-benchmarks/SDM_RICO3D_plt00010 SDM_RICO3D_plt00010

variable nameabsolute errorrelative error
(||A - B||)(||A - B||/||A||)
level = 0
density1.277722816e-091.115457803e-09
rhotheta3.807056714e-071.115670774e-09
x_velocity1.9129229e-071.966504439e-08
y_velocity7.551879122e-091.982345282e-09
z_velocity3.468810566e-075.411458858e-06
temp1.329634074e-074.455797832e-10
theta5.366331379e-081.695226516e-10
pressure0.00015680132491.558893606e-09
qv4.13197445e-112.620460004e-09
qc1.588551932e-315.03267466e-08
qrain0.00.0
qt4.13197445e-112.620460004e-09
qp0.00.0
qsat1.347415894e-106.561294656e-09
rain_accum1.343067705e-311.087840775e-05
rel_humidity6.170439715e-096.669068063e-09
super_droplets_moisture_mass_flux_x1.576420285e-304.027577944e-08
super_droplets_moisture_mass_flux_y6.760838949e-313.848480382e-08
super_droplets_moisture_mass_flux_z3.255684083e-315.794051314e-06
super_droplets_moisture_number_density2.579464604e-165.761496886e-09
super_droplets_moisture_mass_density1.729671208e-313.742032206e-08
super_droplets_moisture_radius3.665406489e-151.238614368e-08
super_droplets_moisture_mass_density_H2O1.718610974e-314.993457578e-08
super_droplets_moisture_mass_flux_x_H2O1.532813089e-305.25947795e-08
super_droplets_moisture_mass_flux_y_H2O6.671015459e-315.100108516e-08
super_droplets_moisture_mass_flux_z_H2O2.413218011e-315.766626627e-06
super_droplets_moisture_aerosol_mass_density_NH4HSO47.151843731e-335.761496823e-09
super_droplets_moisture_aerosol_mass_flux_x_NH4HSO41.544553718e-311.279320124e-08
super_droplets_moisture_aerosol_mass_flux_y_NH4HSO42.623791039e-325.572713508e-09
super_droplets_moisture_aerosol_mass_flux_z_NH4HSO41.771704164e-317.245275059e-06
accum_NH4HSO46.71193213e-261.085350307e-05