<< previous testnext test >>

2026-08-14 / SDM_RICO3D

/scratch/AMReX_RegTesting/amrex/Tools/Plotfile//fcompare.gnu.ex --abort_if_not_all_found -n 0 --rel_tol 1e-12 --abs_tol 1e-12 /scratch/AMReX_RegTesting/rt-ERF/ERF-benchmarks/SDM_RICO3D_plt00010 SDM_RICO3D_plt00010

variable nameabsolute errorrelative error
(||A - B||)(||A - B||/||A||)
level = 0
density3.330669074e-152.907689181e-15
rhotheta3.97903932e-131.166070855e-15
x_velocity1.634248292e-131.680024073e-14
y_velocity1.443289932e-133.788590895e-14
z_velocity2.101721575e-133.278754956e-12
temp7.958078641e-132.666868295e-15
theta7.958078641e-132.51396065e-15
pressure1.89174898e-101.880746473e-15
qv3.469446952e-172.200291188e-15
qc2.633586401e-240.8343437368
qrain0.00.0
qt3.469446952e-172.200291188e-15
qp0.00.0
qsat8.604228441e-164.189862858e-14
rain_accum9.21038363e-270.7460108469
rel_humidity4.385380947e-144.73976011e-14
super_droplets_moisture_mass_flux_x3.265683125e-230.8343456023
super_droplets_moisture_mass_flux_y1.465782465e-230.8343691587
super_droplets_moisture_mass_flux_z4.688242408e-260.8343535838
super_droplets_moisture_number_density3.867623438e-080.863873083
super_droplets_moisture_mass_density3.85658353e-240.8343469968
super_droplets_moisture_radius2.273231616e-117.681705562e-05
super_droplets_moisture_mass_density_H2O2.871582025e-240.8343437368
super_droplets_moisture_mass_flux_x_H2O2.43159315e-230.8343424679
super_droplets_moisture_mass_flux_y_H2O1.091362844e-230.8343661334
super_droplets_moisture_mass_flux_z_H2O3.49158693e-260.8343497301
super_droplets_moisture_aerosol_mass_density_NH4HSO41.072340311e-240.863873083
super_droplets_moisture_aerosol_mass_flux_x_NH4HSO49.006848827e-240.7460176248
super_droplets_moisture_aerosol_mass_flux_y_NH4HSO44.082949651e-240.8671844702
super_droplets_moisture_aerosol_mass_flux_z_NH4HSO42.240581337e-260.9162719358
accum_NH4HSO44.613322115e-210.745995404